Protect-it Maxi Installation

Each Protect-It MaxiTM has 4 pin location holes, two on each side into which the connection pins can be inserted. This choice of holes makes Protect-It MaxiTM expandable to suit multiple column sizes. The best pin location hole for the application will depend on the column size requiring the protection. As a guide, the inner holes are generally used for corners.

Protect-it Maxi Installation

COLUMN SIZE MAXIPAC'S REQUIRED FOR 20" H MAXIPAC'S REQUIRED FOR 40"H

8" X 8" (100mm X 100mm)

6" x 6" (150mm x 150mm)

0.5 1

8" x 8" (200mm x 200mm)

9" x 9" (225mm x 225mm)

10" x 10" (250mm x 250mm)

11" x 11" (275mm x 275mm)

12" x 12" (300mm x 300mm)

& rectangular combinations

1 2

12" x 12" (300mm x 300 mm)

13" x 13" (325 mm x 325mm)

14" x 14" (350 mm x 350mm)

15" x 15" (375 mm x 375mm)

16" x 16" (400mm x 400mm)

17" x 17" (425mm x 425mm)

18" x 18" (450mm x 450 mm)

19" x 19" (475mm x 475mm)

& rectangular combinations

1.5 3

18" x 18" (450mm x 450mm)

19" x 19" (475mm x 475mm)

20" x 20" (500mm x 500mm)

21" x 21" (525mm x 525mm)

22" x 22" (550mm x 550mm)

23" x 23" (575mm x 575mm)

24" x 24" (600mm x 600mm)

& rectangular combinations

2 4

Round 4" (175mm)

Round 5" (200mm)

Round 6"(225mm)

0.5 1

Round 7" (175mm)

Round 8" (200mm)

Round 9" (225mm)

0.75 1.5

Round 10" (250mm)

Round 11" (275mm)

Round 12" (300mm)

Round 13" (325mm)

Round 14" (350mm)

1 2